Runma one axis non-telescopic arm traverse robot
Model: RHD700ID, RHD800ID
Introduction
1. These series are mainly applied to 80-200T horizontal injection molding machines to take out the finished product.
2. Single-stage arms are adopted, the auxiliary arm is added to take out the sprue from 3-plate molds.
3. Traverse stoke is driven by AC servo motor, crosswise and vertical stroke driven by pneumatic pressure.
4. Its stroke and position adjustment can be effected manually.
5. Also the complete set includes standard vacuum and gripper EoAT.
Features: non-telescopic double arm, applicable to simple take-out products, light load
Main Specifications
Model |
Applied to IMM |
Stoke/mm |
Drive mode |
Max Payload
(including EoAT)
/KG |
Time(seconds) |
Net weight
/KG |
Vertical stroke
/mm |
Crosswise stroke
/mm |
Traverse stroke
/mm |
Take-out |
Dry cycle time |
RHD700ID |
80-150T |
700 |
Main arm 170
Auxiliary arm
120 |
1300 |
Z-AC servo Motor X, Y+ pneumatic pressure |
3 |
1.7 |
8.0 |
190 |
RHD800ID |
150-200T |
800 |
1300 |
1.9 |
8.5 |
200 |