Parameter | Index | ||
Measurement Parameter | PM2.5 (Optional PM10) | CO2 | TVOC |
Measurement Range | 0-600μg/m3 | 400-5000ppm | 0-9.999mg/m3 |
Measurement Precision | ≥100μg/m3: ±10%; <100μg/m3: ±10μg/m3 |
±(50ppm + 5% of reading) | Output Resolution 0.001mg/m3 |
Resolution | 1μg/m3 | 1ppm | 0.001mg/m3 |
Warm Up Time/Turn-on Settling Time | ≤4s | ≤30s | ≤3min |
Recovery Time | Recovery Instantly | Recovery Instantly | <60s |
Response Time | ≤4s | / | T90<20s |
Temperature | Accuracy: ±1.5℃; Resolution: 0.1℃ | ||
Humidity | Accuracy: ±5% RH; Resolution: 0.1% RH | ||
Data Interface | UART TTL, 9600 bps | ||
Power Voltage | DC 5±0.5V, Ripple<100mV | ||
Working Current | 200mA | ||
Work Condition | Temperature: 0-50℃; Humidity: 15-90% RH | ||
Storage Condition | Temperature: -20℃-60℃; Humidity: 15-90% RH | ||
Size | 69 mm x 51.5 mm x 18 mm |
PN | Range | Product Type | Packing Specification | L*W*H (mm) |
MM201 | PM2.5: 0-600μg/m3 CO2: 400-5000ppm TVOC: 0-9.999mg/m3 |
PM2.5, CO2, TVOC | 50 pcs/layer, 2 layers/ctn | 510*295*295 |