Failure Analysis and Corrective Measures for Manual Globe Valve Position Indicators

Nov 30, 2026
0 views
Failure Analysis and Corrective Measures for Manual Globe Valve Position Indicators
On this page

Abstract: Manual globe valves are widely used in power generation systems. Their position indicators are essential for operational accuracy, showing whether each valve is in the open or closed position. This paper investigates recurring misalignment of position indicators on manual globe valves manufactured by Suzhou Valve Factory and installed in Units 1 and 2 of the Qinshan Phase II Nuclear Power Plant, which causes loss of accurate and reliable position indication. Manual globe valves are widely used in power generation systems. Their position indicators, which show whether a valve is open or closed, are essential for accurate operation. This paper investigates recurring misalignment of position indicators on manual globe valves manufactured by Suzhou Valve Factory and installed in Units 1 and 2 of the Qinshan Phase II Nuclear Power Plant. This problem results in the loss of reliable position indication.

 

1 Introduction

Manual globe valves manufactured by Suzhou Valve Factory are widely used in various systems at Units 1 and 2 of the Qinshan Phase II Nuclear Power Plant. Each valve primarily consists of four components: a handwheel, a yoke, a position indicator, and a valve body. During routine plant operation, operators turn the handwheel to open or close the valve. When the valve reaches the fully open or fully closed position, the position indicator aligns with the corresponding mark on the scale plate. At the same time, the mechanism limits the vertical movement of the valve stem, keeping the valve in the intended open or closed position. These manual globe valves are used to regulate the flow of media through the nuclear power plant's piping systems.

 

Figure 1. Structure of a Manual Globe Valve and Its Position Indicator Assembly

 

2 Description of Defects

This study analyzes defects in manual globe valves by model over the period from April to September 2021. A total of 20 defects were recorded during this six-month period, averaging 3.33 incidents per month. The distribution by valve model was as follows:

  • SJUSWB-8: 18 defects (90%)
  • SASSWJ-15: 1 defect (5%)
  • SJUSWB-20: 1 defect (5%)

 

Among all models, the SJUSWB-8 had the highest defect frequency. Its 18 recorded defects were classified into the following four categories:

  • Inability to determine whether the valve was open or closed: 15 cases (83%)
  • External leakage: 1 case (6%)
  • Valve jamming: 1 case (6%)
  • Internal leakage: 1 case (5%)

 

The inability to determine the valve's open or closed status was the most common defect. Further analysis of these 15 cases identified three specific causes:

  • Tilted position indicator: 13 cases (87%)
  • Blurred position markings: 1 case (7%)
  • Detached nameplate: 1 case (6%)

A tilted position indicator was therefore the predominant cause, accounting for 87% of cases involving loss of position indication. The position indicator provides visual confirmation of the valve's open or closed status and is essential for accurate operation. If the indicator becomes tilted during operation, the valve position may be misread, resulting in failure of the indication mechanism and potentially compromising system safety.

 

3 Cause Analysis

3.1 Analysis of Operating Torque

In the field, manual globe valves are typically operated using F-shaped wrenches to ensure tight shutoff and facilitate operation. According to the torque relationship, torque increases with wrench length for a given applied force. Most F-shaped wrenches used to operate the defective valves were longer than 250 mm, and excessively long wrenches can generate excessive operating torque.

 

The manufacturer specifies a rated operating torque of M_rated = 24.4 N·m. Excessive closing force subjects the U-bolts to tensile loading; if the resulting tensile stress σ exceeds the yield strength of the U-bolts, they undergo plastic deformation, elongate, and work loose. Given a minimum pulling force of Fmin = 60 N that an adult can exert, the maximum permissible length of the F-shaped wrench is Lmax = Mrated/Fmin ≈ 400 mm.

Fig. 2 Torque requirements and limiting pointer structure

 

Five F-shaped wrenches of different lengths, all within the calculated maximum length of 400 mm, were used to operate the valves. The resulting U-bolt elongation was measured, as summarized below.

Wrench dimensions (diameter × length) (mm)

U-bolt elongation (mm)

14 × 200

0

16 × 250

0

16 × 300

1.6

16 × 350

1.7

18 × 400

2.0

 

The results show that U-bolt elongation decreases with decreasing wrench length. When a wrench with a length of 250 mm or less is used, no permanent elongation occurs in the U-bolts, indicating that they undergo only elastic deformation.

 

Operating tests were also conducted on 10 valves using five F-shaped wrenches with lengths of 200, 250, 300, 350, and 400 mm. The results showed that the incidence of limiting pointer tilt decreased as wrench length decreased. When the wrench length was reduced from 300 mm to 250 mm, the number of valves with correctly aligned pointers increased from 1 to 9. When wrenches 250 mm or shorter were used, none of the 10 valves exhibited pointer tilt. Most of the wrenches used to operate the valves that developed defects in the field were longer than 250 mm. Excessively long wrenches generate higher operating torque, which can cause the limiting pointer to tilt and compromise the accuracy of valve position indication.

 

3.2 Analysis of Friction Coefficient

3.2.1 Analysis of the Contact Area Between the Indicator and the Yoke

Field measurements of the contact area between the valve indicator and the yoke showed that, for valves of the same model, the single-sided contact area ranged from 1.0 to 2.5 cm². Three contact-area ranges were selected for testing: 1.0–1.5 cm², 1.5–2.0 cm², and 2.0–2.5 cm², with 10 valves in each group. Operational tests were conducted using a 250 mm wrench.

In the first group (1.0–1.5 cm²), 9 valves had level indicators, while 1 had a tilted indicator. In the second group (1.5–2.0 cm²), 8 valves had level indicators, while 2 had tilted indicators. In the third group (2.0–2.5 cm²), 9 valves had level indicators, while 1 had a tilted indicator.

The results indicate no appreciable difference in the number of valves with tilted indicators among the three contact-area ranges. Within the tested range of 1.0–2.5 cm², the contact area between the indicator and the yoke had no significant effect on the occurrence of indicator tilt. Its influence on the accuracy of position indication was therefore minimal.

 

3.2.2 Analysis of Pointer–Yoke Contact Surface Roughness

For valves of the same model, the yoke is typically a casting with a machined surface that is subsequently finished by painting or electroplating, resulting in relatively low surface roughness. To investigate the effect of contact surface roughness, the pointer contact surface was polished using sandpaper of different grits (400, 600, 800, 1200, and 1500) to obtain different surface roughness levels, followed by operational tests.

After each polishing stage, the valve was cycled 30 times using a 250 mm F-shaped wrench, and the position of the limiting pointer was observed. The results were as follows:

  • 600-grit sandpaper: The limiting pointer remained horizontal in 26 cycles and tilted in 4.
  • 800-grit sandpaper: The limiting pointer remained horizontal in 25 cycles and tilted in 5.
  • 1000-grit sandpaper: The limiting pointer remained horizontal in 26 cycles and tilted in 4.
  • 1200-grit sandpaper: The limiting pointer remained horizontal in 26 cycles and tilted in 4.
  • 1500-grit sandpaper: The limiting pointer remained horizontal in 26 cycles and tilted in 4.

The results show that although using finer-grit sandpaper reduces the surface roughness of the pointer, it does not produce a consistent change in the frequency of pointer tilt. The effect of contact surface roughness on position indication is therefore considered minimal.

 

3.2.3 Lubrication Analysis

When the handwheel of a manual globe valve is turned, it drives the bronze sleeve to rotate. The sleeve engages with the valve stem through a threaded connection formed by the sleeve's internal threads and the stem's external threads, causing the stem to move upward. Inadequate lubrication of the threaded connection increases friction between the bronze sleeve and the valve stem during operation. This increases the tendency of the stem to rotate about its axis, which in turn causes the indicator to rotate and press more firmly against the yoke. To determine whether lubrication affects indicator tilt, operational tests were conducted on 10 valves before and after lubricant was applied. In both cases, 9 valves had level, properly aligned indicators, while 1 had a tilted indicator. The results therefore show no change in the number of valves with tilted indicators after lubrication. A field survey of 20 valves further confirmed that all were lubricated regularly and that their stem threads were adequately lubricated. These findings indicate that inadequate lubrication of the valve stem threads has minimal influence on position indicator alignment.

 

3.3 Fastening Torque Analysis

3.3.1 U-Bolt Analysis

The U-bolt, also known as a U-shaped bolt, is made of Grade 35 steel and has a yield strength of 275–295 MPa. According to the tensile stress relationship, for a given tensile force, a smaller cross-sectional area, corresponding to a smaller bolt diameter, results in higher tensile stress. The specified diameter of this type of U-bolt is 5 mm, with a tolerance of ±0.2 mm. Inspection of the U-bolts in stock showed that their diameters ranged from 4.8 to 5.20 mm. Measurements of U-bolts removed from 13 valves that exhibited indicator tilt between July and December 2021 showed diameters ranging from 4.96 to 5.11 mm. The smallest diameter among the U-bolts associated with the field defects was 4.96 mm. Even at a diameter of 4.84 mm, which is smaller than the minimum diameter of the U-bolts associated with the field defects, the U-bolts did not become loose or cause indicator tilt. Therefore, U-bolt diameter has a negligible effect on valve position indication.

 

3.3.2 Analysis of U-Bolt Tightening Torque

The U-bolt is secured at both ends with M6 nuts. Valve operation tests were conducted using the minimum recommended tightening torque. At a tightening torque of 4 N·m, the position indicator remained horizontal and accurately indicated the fully open and fully closed positions. No indicator tilt was observed at this minimum tightening torque. On-site inspections confirmed that the tightening torque of the U-bolt nuts ranged from 4 to 5 N·m, indicating that variations in tightening torque within this range have minimal effect on position indication.

 

3.4 Position Indicator Play Analysis

The clearance between the slot and the position indicator determines the amount of play in the indicator. Measurements of field valves exhibiting this defect showed that, in 8 out of 10 cases, the clearance between the slot and the position indicator exceeded 2.8 mm. The limiting pointer and its slot form a clearance fit. Measurements of 30 valves in stock gave limiting-pointer dimensions of 11.90–13.30 mm and slot dimensions of 14.30–15.90 mm, yielding a maximum fit clearance of Δ X = 15.9−11.9 = 4 mm and a minimum fit clearance of Δ y = 14.3−13.3 = 1 mm.

 

Fig. 3 Results of the operation tests

 

After measuring the dimensions of the slot and position indicator, operational tests were conducted on the valves in stock. The results showed that when the clearance exceeded 2.80 mm, the indicator tilted noticeably during operation and could no longer accurately indicate the fully open or fully closed position. The test results indicate that when the clearance between the limiting pointer and its slot is 2.80 mm or greater, noticeable pointer tilt is likely to occur during operation. Excessive clearance at this interface therefore has a significant adverse effect on the accuracy of valve position indication.

 

3.5 Summary of Root Cause Analysis

In summary, the primary causes of failure in the position indication mechanism of manual globe valves are excessive operating torque and excessive play in the limiting pointer. Field investigations showed that the F-shaped wrenches used to operate valves that developed defects were generally longer than 250 mm. Such long wrenches generate excessive operating torque, which can cause the limiting pointer to tilt and lead to failure of the position indication mechanism. In addition, when the clearance between the limiting pointer and its slot is 2.80 mm or greater, the pointer is prone to noticeable tilting during operation, resulting in inaccurate valve position indication.

 

4 Corrective Measures

Based on the root cause analysis, failures of the position indication mechanism in manual globe valves can be reduced through two measures: using 200 mm or 250 mm F-shaped wrenches for field operations and increasing the width of the position indicator.

 

4.1 F-Wrench Length Control

All F-shaped wrenches used to operate manual globe valves in the field must be limited to a maximum length of 250 mm. Only 200 mm or 250 mm wrenches are permitted.

(1) Implementation of a Tool Loan Register

Assign specific wrenches (L ≤ 250 mm) to individual valve tag numbers and establish a tool loan register to standardize wrench use. Before borrowing an F-shaped wrench, operators must provide the tag number of the valve to be operated. The register is then used to identify the appropriate wrench length for that valve. This measure ensures that only wrenches no longer than 250 mm are used to operate manual globe valves.

 

(2) On-Site Visual Reminders

Warning signs indicating the maximum permissible wrench length were prepared and attached to the handwheels of the globe valves to remind operators to use wrenches of the appropriate length. After implementation of this measure, an inspection confirmed that all wrenches in use were no longer than 250 mm.

 

4.2 Increasing the Width of the Limiting Pointer

Based on the existing slot width and the required fit clearance, the width of the limiting pointer was increased to 13.1–13.30 mm. Revised engineering drawings were prepared for the limiting pointer, specifying the updated nominal width and dimensional tolerances. Existing limiting pointers in the field that did not meet the revised specifications were modified to achieve a width within the 13.1–13.30 mm range. After implementation of this measure, all modified pointers were measured and confirmed to meet the specified width range.

 

Fig. 4 Increasing the Width of the Limiting Pointer

 

4.3 Evaluation of the Corrective Measures

Change in Defect Rate

From January to June 2022, only 2 defects were recorded in the manual globe valves, averaging 0.33 defects per month. This represents a 90.1% reduction compared with the average of 3.33 defects per month recorded from April to September 2021. Regarding limiting pointer tilt, 13 cases were recorded before the corrective measures were implemented, whereas no such cases occurred after implementation. The incidence of limiting pointer tilt therefore decreased significantly, indicating that the corrective measures effectively resolved the recurring position indication problem in manual globe valves.

 

5 Conclusion

Manual globe valves are widely used in various systems of nuclear power plants to regulate media flow. Their limiting pointers, which indicate whether a valve is open or closed, are essential for accurate valve operation. By analyzing operating torque, friction, fastening torque, and limiting pointer clearance, this study identified excessive operating torque and excessive clearance between the limiting pointer and its slot as the primary causes of position indication failure. To address these issues, two corrective measures were implemented: restricting the use of F-shaped wrenches to lengths of 200 mm or 250 mm and increasing the width of the limiting pointer. These measures significantly reduced the incidence of position indication failures and improved the reliability of valve position indication in manual globe valves.